CNT241-MIB DEFINITIONS::=BEGINIMPORTSMODULE-IDENTITY,OBJECT-TYPEFROM SNMPv2-SMI
DisplayStringFROM SNMPv2-TC
TRAP-TYPEFROM RFC-1215
sysName
FROM RFC1213-MIB
cnt2Subagent
FROM CNT2-MIB
cnt2SysSerialNumber
FROM CNT251-MIB;-- the CNT Service Monitorcnt2Sm MODULE-IDENTITYLAST-UPDATED"0312050000Z"-- Dec 05, 2003ORGANIZATION"Computer Network Technology Corporation"CONTACT-INFO"Computer Network Technology Technical Support
6000 Nathan Lane North
Plymouth, Minnesota 55442
support: +1-763-268-6600
free: +1-800-762-8061
email: customer_support@cnt.com"
DESCRIPTION"This defines the CNT Service Monitor MIB."REVISION"0312050000Z"-- Dec 05, 2003DESCRIPTION"Version 1.11:
Updated for sysName and cnt2SysSerialNumber
to be included in new traps with sub-id's
[17..24] that replaced traps with sub-id's
[9..16]."REVISION"0301290000Z"-- Jan 29, 2003DESCRIPTION"Version 1.10:
Updated to SMI V2.
Updated contact information."REVISION"0001010000Z"-- Jan 01, 2000DESCRIPTION"Version 1.9:
Changed cnt2SmMsgSeverity and cnt2SmMsgToTrapFilter
to have the severity level starting out at 0
instead of 1 to match CNT's message manual."REVISION"0001010000Z"-- Jan 01, 2000DESCRIPTION"Version 1.8:
Changed read_write read_only to
read-write-access and read-only-access
because Mosy compiler doesn't support
Underscore."REVISION"0001010000Z"-- Jan 01, 2000
DESCRIPTION"Version 1.7:
Changed SmMessageIndex to be after SmMessageText
because of a compatibility problem with CMF vs
Advantnet."REVISION"0001010000Z"-- Jan 01, 2000DESCRIPTION"Version 1.6:
Changed read-write(1) to read_read(1)
because some compilers do not handle
it correctly."REVISION"0001010000Z"-- Jan 01, 2000DESCRIPTION"Version 1.5:
Changed syntax to compile with Advantnet."REVISION"0001010000Z"-- Jan 01, 2000DESCRIPTION"Created."::={ cnt2Subagent 1}-- the CNT Service Monitor groupscnt2SmHw OBJECTIDENTIFIER::={ cnt2Sm 1}-- Hardwarecnt2SmSw OBJECTIDENTIFIER::={ cnt2Sm 2}-- Software-- cnt2SmMsg has been deprecated and replaced by cnt2SmMessage
cnt2SmMsg OBJECTIDENTIFIER::={ cnt2Sm 3}-- Messagescnt2SmMessage OBJECTIDENTIFIER::={ cnt2Sm 4}-- Messages-- Service Monitor Hardware-- cnt2SmHw OBJECT IDENTIFIER ::= { cnt2Subagent 1 }-- Service Monitor Hardware Probecnt2SmHwTemperatureF OBJECT-TYPESYNTAXINTEGERMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The temperature in Farenheit of the node in
the range (0..255).
If/when the temperature transitions from below
113 degrees to above 113 degrees, a advisory trap
will be sent.
If/when the temperature transitions from below
131 degrees to above 131 degrees, a repair trap
will be sent."::={ cnt2SmHw 1}cnt2SmHwTapeDriveState OBJECT-TYPESYNTAXINTEGER{not-present(1),
ok(2),failed(3)}MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The state of the DAT tape drive."::={ cnt2SmHw 2}cnt2SmHwCdRomDriveState OBJECT-TYPESYNTAXINTEGER{not-present(1),ok(2),failed(3)}MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The state of the CD drive."::={ cnt2SmHw 3}cnt2SmHwTapeMounted OBJECT-TYPESYNTAXINTEGER{
not-applicable(1),empty(2),mounted(3)}MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Indicates whether the DAT tape drive contains a
tape."::={ cnt2SmHw 4}cnt2SmHwCdRomMounted OBJECT-TYPESYNTAXINTEGER{not-applicable(1),empty(2),mounted(3)}MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"Indicates whether the CD drive contains a CD."::={ cnt2SmHw 5}
cnt2SmHwServiceLed OBJECT-TYPESYNTAXINTEGER{off(1),on(2)}MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The state of the service LED."::={ cnt2SmHw 6}cnt2SmHwIplSwitch OBJECT-TYPESYNTAXINTEGER{off(1),on(2)}MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The state of the IPL switch."::={ cnt2SmHw 7}cnt2SmHwAdapterTable OBJECT-TYPE
SYNTAXSEQUENCEOF Cnt2SmHwAdapterEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"List of adapters in the node."::={ cnt2SmHw 8}cnt2SmHwAdapterEntry OBJECT-TYPESYNTAX Cnt2SmHwAdapterEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"A adapter entry."INDEX{ cnt2SmHwAdapterIndex }::={ cnt2SmHwAdapterTable 1}
Cnt2SmHwAdapterEntry ::=SEQUENCE{
cnt2SmHwAdapterIndex
INTEGER,
cnt2SmHwAdapterOperState
INTEGER,
cnt2SmHwAdapterAdminState
INTEGER}cnt2SmHwAdapterIndex OBJECT-TYPESYNTAXINTEGERMAX-ACCESSread-only
STATUScurrentDESCRIPTION"The relative index of this adapter entry
within the node."::={ cnt2SmHwAdapterEntry 1}cnt2SmHwAdapterOperState OBJECT-TYPESYNTAXINTEGER{ok(1),not-ok(2)}MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The state of the adapter in this slot."::={ cnt2SmHwAdapterEntry 2}cnt2SmHwAdapterAdminState OBJECT-TYPESYNTAXINTEGER{enabled(1),disabled(2),reset(3)}
MAX-ACCESSread-writeSTATUScurrentDESCRIPTION"The state of the adapter in this slot."::={ cnt2SmHwAdapterEntry 3}cnt2SmHwCardTable OBJECT-TYPESYNTAXSEQUENCEOF Cnt2SmHwCardEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"List of adapters in the node."::={ cnt2SmHw 9}cnt2SmHwCardEntry OBJECT-TYPESYNTAX Cnt2SmHwCardEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"A adapter entry."INDEX{ cnt2SmCardAdapterIndex, cnt2SmHwCardIndex }::={ cnt2SmHwCardTable 1}
Cnt2SmHwCardEntry ::=SEQUENCE{
cnt2SmCardAdapterIndex
INTEGER,
cnt2SmHwCardIndex
INTEGER,
cnt2SmHwCardOperState
INTEGER,
cnt2SmHwCardAdminState
INTEGER}cnt2SmCardAdapterIndex OBJECT-TYPESYNTAXINTEGERMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The relative index of this adapter entry
within the node."::={ cnt2SmHwCardEntry 1}cnt2SmHwCardIndex OBJECT-TYPESYNTAXINTEGERMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The relative index of this adapter entry
within the node."::={ cnt2SmHwCardEntry 2}cnt2SmHwCardOperState OBJECT-TYPESYNTAXINTEGER{ok(1),
not-ok(2)}MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The state of the adapter in this slot."::={ cnt2SmHwCardEntry 3}cnt2SmHwCardAdminState OBJECT-TYPESYNTAXINTEGER{enabled(1),disabled(2),reset(3)}MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The state of the adapter in this slot."::={ cnt2SmHwCardEntry 4}cnt2SmHwPowerSupplyTable OBJECT-TYPESYNTAXSEQUENCEOF Cnt2SmHwPowerSupplyEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"List of power supplies in the node."::={ cnt2SmHw 10}cnt2SmHwPowerSupplyEntry OBJECT-TYPESYNTAX Cnt2SmHwPowerSupplyEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"A power supply entry."INDEX{ cnt2SmHwPowerSupplyIndex }::={ cnt2SmHwPowerSupplyTable 1}
Cnt2SmHwPowerSupplyEntry ::=SEQUENCE{
cnt2SmHwPowerSupplyIndex
INTEGER,
cnt2SmHwPowerSupplyACState
INTEGER,
cnt2SmHwPowerSupplyDCState
INTEGER}cnt2SmHwPowerSupplyIndex OBJECT-TYPESYNTAXINTEGERMAX-ACCESSread-onlySTATUScurrent
DESCRIPTION"The relative index of this power supply entry
within the node."::={ cnt2SmHwPowerSupplyEntry 1}cnt2SmHwPowerSupplyACState OBJECT-TYPESYNTAXINTEGER{ok(1),not-ok(2),absent(3)}MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The AC state of this power supply."::={ cnt2SmHwPowerSupplyEntry 2}cnt2SmHwPowerSupplyDCState OBJECT-TYPESYNTAXINTEGER{ok(1),not-ok(2),absent(3)
}MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The DC state of this power supply."::={ cnt2SmHwPowerSupplyEntry 3}cnt2SmHwFanTable OBJECT-TYPESYNTAXSEQUENCEOF Cnt2SmHwFanEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"List of power supplies in the node."::={ cnt2SmHw 11}cnt2SmHwFanEntry OBJECT-TYPESYNTAX Cnt2SmHwFanEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"A fan entry."INDEX{ cnt2SmHwFanIndex }::={ cnt2SmHwFanTable 1}
Cnt2SmHwFanEntry ::=SEQUENCE{
cnt2SmHwFanIndex
INTEGER,
cnt2SmHwFanState
INTEGER}cnt2SmHwFanIndex OBJECT-TYPESYNTAXINTEGERMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The relative index of this fan entry
within the node."::={ cnt2SmHwFanEntry 1}cnt2SmHwFanState OBJECT-TYPESYNTAXINTEGER{ok(1),not-ok(2)}MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The state of this fan."::={ cnt2SmHwFanEntry 2}-- Service Monitor Software-- cnt2SmSw OBJECT IDENTIFIER ::= { cnt2Subagent 2 }cnt2SmNumModules OBJECT-TYPE
SYNTAXINTEGERMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The number of software modules making up the set
referred to as the Service Monitor."::={ cnt2SmSw 1}cnt2SmSwTable OBJECT-TYPESYNTAXSEQUENCEOF Cnt2SmSwEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"List of entries in the service monitor software
module table."::={ cnt2SmSw 2}cnt2SmSwEntry OBJECT-TYPESYNTAX Cnt2SmSwEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"A service monitor software module entry."INDEX{ cnt2SmSwIndex }::={ cnt2SmSwTable 1}
Cnt2SmSwEntry ::=SEQUENCE{
cnt2SmSwIndex
INTEGER,
cnt2SmSwName
DisplayString,
cnt2SmSwFunction
INTEGER,
cnt2SmSwMajorVersion
INTEGER,
cnt2SmSwMinorVersion
INTEGER}cnt2SmSwIndex OBJECT-TYPESYNTAXINTEGERMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The relative index of this software module entry
within the service monitor."::={ cnt2SmSwEntry 1}cnt2SmSwName OBJECT-TYPESYNTAXDisplayStringMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The name of the service monitor module."::={ cnt2SmSwEntry 2}cnt2SmSwFunction OBJECT-TYPE
SYNTAXINTEGER{loading(1),dumping(2),configuration(3),messages(4),hw-monitoring(5),tracing(6),snmp-master-agent(7),console(8),utilities(9)}MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The primary function performed by this
software module."::={ cnt2SmSwEntry 3}cnt2SmSwMajorVersion OBJECT-TYPESYNTAXINTEGER
MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The major version number of this software
module."::={ cnt2SmSwEntry 4}cnt2SmSwMinorVersion OBJECT-TYPESYNTAXINTEGERMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The minor version number of this software
module."::={ cnt2SmSwEntry 5}cnt2SmSwSlot OBJECT-TYPESYNTAXINTEGERMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The slot number of the active Service Monitor."::={ cnt2SmSw 3}cnt2SmSwAccess OBJECT-TYPESYNTAXINTEGER{read-write-access(1),
read-only-access(2)}MAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The access permissions of the active Service Monitor."::={ cnt2SmSw 4}-- **************************************************************-- * The following messages table is deprecated. It has been *-- * replaced by cnt2SmMessage. *-- **************************************************************-- Service Monitor Messages-- cnt2SmMsg OBJECT IDENTIFIER ::= { cnt2Sm 3 }cnt2SmNumMsgs OBJECT-TYPESYNTAXINTEGERMAX-ACCESSread-onlySTATUSdeprecatedDESCRIPTION"The number of messages in the system message
file that have been entered by all modules within
the node."::={ cnt2SmMsg 1}
cnt2SmMsgTable OBJECT-TYPESYNTAXSEQUENCEOF Cnt2SmMsgEntry
MAX-ACCESSnot-accessibleSTATUSdeprecatedDESCRIPTION"List of entries in the service monitor message
file. This file contains any messages that has
been entered by any software residing in the node."::={ cnt2SmMsg 2}cnt2SmMsgEntry OBJECT-TYPESYNTAX Cnt2SmMsgEntry
MAX-ACCESSnot-accessibleSTATUSdeprecatedDESCRIPTION"A message file entry."INDEX{ cnt2SmMsgIndex }::={ cnt2SmMsgTable 1}
Cnt2SmMsgEntry ::=SEQUENCE{
cnt2SmMsgIndex
INTEGER,
cnt2SmMsgSeverity
INTEGER,
cnt2SmMsgProcessName
DisplayString,
cnt2SmMsgNumber
INTEGER,
cnt2SmMsgSlotNumber
DisplayString,
cnt2SmMsgDateTime
DisplayString,
cnt2SmMsgErrorNumber
INTEGER,
cnt2SmMsgContent
DisplayString}cnt2SmMsgIndex OBJECT-TYPESYNTAXINTEGERMAX-ACCESSread-onlySTATUSdeprecatedDESCRIPTION"The relative index of this message entry
within the message file."::={ cnt2SmMsgEntry 1}cnt2SmMsgSeverity OBJECT-TYPESYNTAXINTEGER{emergency(0),alert(1),criticial(2),error(3),
warning(4),notice(5),information(6),debug(7)}MAX-ACCESSread-onlySTATUSdeprecatedDESCRIPTION"The severity of this message."::={ cnt2SmMsgEntry 2}cnt2SmMsgProcessName OBJECT-TYPESYNTAXDisplayStringMAX-ACCESSread-onlySTATUSdeprecatedDESCRIPTION"The name of the process that sent this
message to the message server."::={ cnt2SmMsgEntry 3}cnt2SmMsgNumber OBJECT-TYPESYNTAXINTEGERMAX-ACCESSread-onlySTATUSdeprecated
DESCRIPTION"The number of this message. Each module
numbers its message type as another way of
describing it. This message can then be
cross-referenced in the CNT system messages
reference manual."::={ cnt2SmMsgEntry 4}cnt2SmMsgSlotNumber OBJECT-TYPESYNTAXDisplayStringMAX-ACCESSread-onlySTATUSdeprecatedDESCRIPTION"The slot number of the module that sent this
message to the message server."::={ cnt2SmMsgEntry 5}cnt2SmMsgDateTime OBJECT-TYPESYNTAXDisplayStringMAX-ACCESSread-onlySTATUSdeprecatedDESCRIPTION"The date and time that this message was sent
to the message server."::={ cnt2SmMsgEntry 6}cnt2SmMsgErrorNumber OBJECT-TYPE
SYNTAXINTEGERMAX-ACCESSread-onlySTATUSdeprecatedDESCRIPTION"The number of the Error message which caused us
to generate this error message. Each module
numbers its message errors as another way of
describing it."::={ cnt2SmMsgEntry 7}cnt2SmMsgContent OBJECT-TYPESYNTAXDisplayStringMAX-ACCESSread-onlySTATUSdeprecatedDESCRIPTION"The textual detail of the message sent to
the message server."::={ cnt2SmMsgEntry 8}-- **************************************************************-- * The following messages table replaces the cnt2SmMsg table *-- * which has been deprecated. *-- **************************************************************-- Service Monitor Messages-- cnt2SmMessage OBJECT IDENTIFIER ::= { cnt2Sm 4 }cnt2SmMsgTableSize OBJECT-TYPE
SYNTAXINTEGERMAX-ACCESSread-writeSTATUScurrentDESCRIPTION"The number of messages that are available through
SNMP access. This message table is limited to the
most recent number messages specified by this object."::={ cnt2SmMessage 1}cnt2SmMessageTable OBJECT-TYPESYNTAXSEQUENCEOF Cnt2SmMessageEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"List of entries in the service monitor message
file. This file contains any messages that has
been entered by any software residing in the node."::={ cnt2SmMessage 2}cnt2SmMessageEntry OBJECT-TYPESYNTAX Cnt2SmMessageEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"A message file entry."
INDEX{cnt2SmMessageText }::={ cnt2SmMessageTable 1}-- The SmMessageText and SmMessageIndex was in this order because we want
-- to provide downward compatible between differrent version of MIBS out there.
Cnt2SmMessageEntry ::=SEQUENCE{
cnt2SmMessageText
DisplayString,
cnt2SmMessageIndex
INTEGER}cnt2SmMessageText OBJECT-TYPESYNTAXDisplayStringMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The textual detail of the message sent to
the message server."::={ cnt2SmMessageEntry 1}cnt2SmMessageIndex OBJECT-TYPESYNTAXINTEGERMAX-ACCESSread-onlySTATUScurrentDESCRIPTION"The textual index of the message sent to
the message server."
::={ cnt2SmMessageEntry 2}cnt2SmMsgToTrapFilter OBJECT-TYPESYNTAXINTEGER{emergency(0),alert(1),criticial(2),error(3),warning(4),notice(5),information(6),debug(7)}MAX-ACCESSread-writeSTATUScurrentDESCRIPTION"Messages in cnt2SmMessageTable can be sent as
traps to selected destinations. However, the
messages are filtered by severity before they
are forwarded as traps. This object determines
which of the messages are filtered. All messages
with severity equal and lower in value than the
value of this object are forwarded as traps.
Severity levels range from 0 (lowest) to 7
(highest)."::={ cnt2SmMessage 3}-- **************************************************************-- * The following traps 1-8 have been replaced by traps 9-16 *-- **************************************************************cnt2smEmergencyMsg TRAP-TYPEENTERPRISE cnt2Sm
VARIABLES{ cnt2SmMsgProcessName,
cnt2SmMsgNumber,
cnt2SmMsgSlotNumber,
cnt2SmMsgDateTime,
cnt2SmMsgErrorNumber,
cnt2SmMsgContent }DESCRIPTION"An emergency level trap (0) signifies that an
event has occured which has rendered the system
unusable. All modules and interfaces will be
affected."::=1cnt2smAlertMsg TRAP-TYPEENTERPRISE cnt2Sm
VARIABLES{ cnt2SmMsgProcessName,
cnt2SmMsgNumber,
cnt2SmMsgSlotNumber,
cnt2SmMsgDateTime,
cnt2SmMsgErrorNumber,
cnt2SmMsgContent }DESCRIPTION"An Alert level trap (1) signifies that an
event has occured which requires that immediate
action be taken. The module will be affected."::=2cnt2smCriticalMsg TRAP-TYPEENTERPRISE cnt2Sm
VARIABLES{ cnt2SmMsgProcessName,
cnt2SmMsgNumber,
cnt2SmMsgSlotNumber,
cnt2SmMsgDateTime,
cnt2SmMsgErrorNumber,
cnt2SmMsgContent }DESCRIPTION"A Critical level trap (1) signifies that an
event has occured for which action should be
taken. The module will be affected."::=3cnt2smErrorMsg TRAP-TYPEENTERPRISE cnt2Sm
VARIABLES{ cnt2SmMsgProcessName,
cnt2SmMsgNumber,
cnt2SmMsgSlotNumber,
cnt2SmMsgDateTime,
cnt2SmMsgErrorNumber,
cnt2SmMsgContent }DESCRIPTION"An Error level trap (3) signifies that an
event has occured that has resulted in errors.
The module will probably be affected."::=4cnt2smWarningMsg TRAP-TYPEENTERPRISE cnt2Sm
VARIABLES{ cnt2SmMsgProcessName,
cnt2SmMsgNumber,
cnt2SmMsgSlotNumber,
cnt2SmMsgDateTime,
cnt2SmMsgErrorNumber,
cnt2SmMsgContent }DESCRIPTION"A Warning level trap (4) signifies that an
event has occured that may affect the module."::=5cnt2smNoticeMsg TRAP-TYPEENTERPRISE cnt2Sm
VARIABLES{ cnt2SmMsgProcessName,
cnt2SmMsgNumber,
cnt2SmMsgSlotNumber,
cnt2SmMsgDateTime,
cnt2SmMsgErrorNumber,
cnt2SmMsgContent }DESCRIPTION"A Notice level trap (1) signifies that an
event has occured that is normal but that has
significance. The module should be unaffected"::=6cnt2smInfoMsg TRAP-TYPEENTERPRISE cnt2Sm
VARIABLES{ cnt2SmMsgProcessName,
cnt2SmMsgNumber,
cnt2SmMsgSlotNumber,
cnt2SmMsgDateTime,
cnt2SmMsgErrorNumber,
cnt2SmMsgContent }DESCRIPTION"An Information level trap (6) signifies that an
event has occured that informational in severity
and that the module will not be affected by this
error."::=7cnt2smDebugMsg TRAP-TYPEENTERPRISE cnt2Sm
VARIABLES{ cnt2SmMsgProcessName,
cnt2SmMsgNumber,
cnt2SmMsgSlotNumber,
cnt2SmMsgDateTime,
cnt2SmMsgErrorNumber,
cnt2SmMsgContent }DESCRIPTION"A Debug level trap (7) signifies that an
event has occured at a debug level that is
informational. The module will not be
affected by this error."::=8-- **************************************************************-- * The following traps 9-16 have replaced traps 1-8 *-- * The following traps 9-16 have been replaced by traps 17-24 *-- **************************************************************cnt2smEmergencyTrap TRAP-TYPEENTERPRISE cnt2Sm
VARIABLES{ cnt2SmMessageText }DESCRIPTION"An emergency level trap signifies that an
event has occured which has rendered the system
unusable. All modules and interfaces will be
affected."::=9cnt2smAlertTrap TRAP-TYPEENTERPRISE cnt2Sm
VARIABLES{ cnt2SmMessageText }DESCRIPTION
"An Alert level trap signifies that an
event has occured which requires that immediate
action be taken. The module will be affected."::=10cnt2smCriticalTrap TRAP-TYPEENTERPRISE cnt2Sm
VARIABLES{ cnt2SmMessageText }DESCRIPTION"A Critical level trap signifies that an
event has occured for which action should be
taken. The module will be affected."::=11cnt2smErrorTrap TRAP-TYPEENTERPRISE cnt2Sm
VARIABLES{ cnt2SmMessageText }DESCRIPTION"An Error level trap signifies that an
event has occured that has resulted in errors.
The module will probably be affected."::=12cnt2smWarningTrap TRAP-TYPEENTERPRISE cnt2Sm
VARIABLES{ cnt2SmMessageText }DESCRIPTION"A Warning level trap signifies that an
event has occured that may affect the module."::=13cnt2smNoticeTrap TRAP-TYPEENTERPRISE cnt2Sm
VARIABLES{ cnt2SmMessageText }DESCRIPTION"A Notice level trap signifies that an
event has occured that is normal but that has
significance. The module should be unaffected"::=14cnt2smInfoTrap TRAP-TYPEENTERPRISE cnt2Sm
VARIABLES{ cnt2SmMessageText }DESCRIPTION"An Information level trap signifies that an
event has occured that informational in severity
and that the module will not be affected by this
error."::=15cnt2smDebugTrap TRAP-TYPEENTERPRISE cnt2Sm
VARIABLES{ cnt2SmMessageText }DESCRIPTION"A Debug level trap signifies that an
event has occured at a debug level that is
informational. The module will not be
affected by this error."
::=16-- **************************************************************-- * The following traps 17-24 have replaced traps 9-16 *-- **************************************************************cnt2smEmergencyTrap1 TRAP-TYPEENTERPRISE cnt2Sm
VARIABLES{ sysName,
cnt2SysSerialNumber,
cnt2SmMessageText }DESCRIPTION"An emergency level trap signifies that an
event has occured which has rendered the system
unusable. All modules and interfaces will be
affected."::=17cnt2smAlertTrap1 TRAP-TYPEENTERPRISE cnt2Sm
VARIABLES{ sysName,
cnt2SysSerialNumber,
cnt2SmMessageText }DESCRIPTION"An Alert level trap signifies that an
event has occured which requires that immediate
action be taken. The module will be affected."::=18cnt2smCriticalTrap1 TRAP-TYPE
ENTERPRISE cnt2Sm
VARIABLES{ sysName,
cnt2SysSerialNumber,
cnt2SmMessageText }DESCRIPTION"A Critical level trap signifies that an
event has occured for which action should be
taken. The module will be affected."::=19cnt2smErrorTrap1 TRAP-TYPEENTERPRISE cnt2Sm
VARIABLES{ sysName,
cnt2SysSerialNumber,
cnt2SmMessageText }DESCRIPTION"An Error level trap signifies that an
event has occured that has resulted in errors.
The module will probably be affected."::=20cnt2smWarningTrap1 TRAP-TYPEENTERPRISE cnt2Sm
VARIABLES{ sysName,
cnt2SysSerialNumber,
cnt2SmMessageText }DESCRIPTION"A Warning level trap signifies that an
event has occured that may affect the module."::=21cnt2smNoticeTrap1 TRAP-TYPEENTERPRISE cnt2Sm
VARIABLES{ sysName,
cnt2SysSerialNumber,
cnt2SmMessageText }DESCRIPTION"A Notice level trap signifies that an
event has occured that is normal but that has
significance. The module should be unaffected"::=22cnt2smInfoTrap1 TRAP-TYPEENTERPRISE cnt2Sm
VARIABLES{ sysName,
cnt2SysSerialNumber,
cnt2SmMessageText }DESCRIPTION"An Information level trap signifies that an
event has occured that informational in severity
and that the module will not be affected by this
error."::=23cnt2smDebugTrap1 TRAP-TYPEENTERPRISE cnt2Sm
VARIABLES{ sysName,
cnt2SysSerialNumber,
cnt2SmMessageText }DESCRIPTION"A Debug level trap signifies that an
event has occured at a debug level that is
informational. The module will not be
affected by this error."::=24END